{"id":2353,"date":"2025-03-09T06:34:53","date_gmt":"2025-03-09T05:34:53","guid":{"rendered":"https:\/\/www.fas-northafrica.com\/?page_id=2353"},"modified":"2025-03-09T06:34:54","modified_gmt":"2025-03-09T05:34:54","slug":"pd-meters-liquid-controls","status":"publish","type":"page","link":"https:\/\/www.fas-northafrica.com\/fr\/products\/metering-units\/pd-meters-liquid-controls\/","title":{"rendered":"<strong>PD METERS LIQUID CONTROLS<\/strong>"},"content":{"rendered":"[vc_column_text css=\u00a0\u00bb.vc_custom_1564140538620{background-color: #f5f5f5 !important;}\u00a0\u00bb]\n<p style=\"text-align: center; margin-top: -35px;\"><span style=\"font-size: 12pt; color: #808080;\"><span class=\"ourproducts\" style=\"font-family: Poppins;\"><a class=\"black\" href=\"https:\/\/www.fas-northafrica.com\/index.php\/products\/\"><span class=\"lien\" style=\"color: #333333;\">OUR PRODUCTS<\/span><\/a>&nbsp;<\/span> <img class=\"file\" src=\"https:\/\/www.fas-northafrica.com\/wp-content\/uploads\/2019\/07\/1.png\"><span style=\"font-family: Poppins; color: #e64320;\">&nbsp; Metering Units<\/span><\/span><\/p>\n[\/vc_column_text]\n\n\n\n[vc_row_inner][vc_column_inner width=\u00a0\u00bb1\/2&Prime;][vc_single_image image=\u00a0\u00bb482&Prime; img_size=\u00a0\u00bbfull\u00a0\u00bb][\/vc_column_inner][vc_column_inner width=\u00a0\u00bb1\/2&Prime;][vc_column_text css=\u00a0\u00bb.vc_custom_1588858469372{margin-right: 50px !important;margin-left: 50px !important;}\u00a0\u00bb]\n\n\n\n<h4>PD METERS LIQUID CONTROLS<\/h4>\n\n\n\n<p><strong>PD METERS SAMPI<\/strong><\/p>\n\n\n\n<h3><strong>For road tankers and stationery applications&nbsp; for LPG<\/strong><\/h3>\n\n\n\n<figure class=\"wp-block-gallery has-nested-images columns-default is-cropped\">\n<figure class=\"wp-block-image\"><a href=\"https:\/\/www.fas.de\/files\/FAS%20Dateien\/Produkte\/Messtechnik\/18793_result.jpg\"><img src=\"https:\/\/www.fas.de\/files\/FAS%20Dateien\/Produkte\/Messtechnik\/18793_result.jpg\" alt=\"For road tankers and stationery applications\u00a0 for LPG\"\/><\/a><figcaption>METERS LIQUID CONTROLS <strong>For road tankers and stationery applications&nbsp; for LPG<\/strong><\/figcaption><\/figure>\n<\/figure>\n\n\n\n<h2><strong>complete measuring unit typ LC MA5-LC MA7 &#8211; LC MA15 (PD meter)<\/strong><\/h2>\n\n\n\n<h3><strong>PD METER in ready to use design<\/strong><\/h3>\n\n\n\n<ul><li>back check valve  inlet<\/li><li>vapor eliminator<\/li><li>LC PD Meter<\/li><li>mechanical counter Typ VR WITH or WITHOUT printer<\/li><li>differential valve<\/li><li>flow direction: left &#8211; right<\/li><li>BUNA seals<\/li><\/ul>\n\n\n\n<figure id=\"table_22771\" class=\"wp-block-table is-style-stripes\"><table><thead><tr><th>FAS -Nr.<\/th><th>TYP<\/th><th>capacity [l\/min]<\/th><th>MWP [PN]<\/th><th>housing<\/th><th>version<\/th><th>weight [kg]<\/th><th>connections (DN)<\/th><\/tr><\/thead><tbody><tr><th scope=\"row\">18792<\/th><td>MA-5-GX-10<\/td><td>20-227<\/td><td>25<\/td><td>Aluminium<\/td><td>A<\/td><td>37<\/td><td>1 1\/2&Prime;<\/td><\/tr><tr><th scope=\"row\">18932<\/th><td>MA-5-GY-10<\/td><td>45-227<\/td><td>25<\/td><td>Aluminium<\/td><td>B<\/td><td>40<\/td><td>1 1\/2&Prime;<\/td><\/tr><tr><th scope=\"row\">187935<\/th><td>MA-7-GX-10<\/td><td>75-380<\/td><td>25<\/td><td>Aluminium<\/td><td>A<\/td><td>44<\/td><td>2&Prime;<\/td><\/tr><tr><th scope=\"row\">187936<\/th><td>MA-7-GX-10<\/td><td>75-380<\/td><td>25<\/td><td>Aluminium<\/td><td>C<\/td><td>43<\/td><td>2&Prime;<\/td><\/tr><tr><th scope=\"row\">18904<\/th><td>MA-7-GY-10<\/td><td>75-380<\/td><td>25<\/td><td>Aluminium<\/td><td>B<\/td><td>49<\/td><td>2&Prime;<\/td><\/tr><tr><th scope=\"row\">981641<\/th><td>MA-7-TEX<\/td><td>75-380<\/td><td>25<\/td><td>Aluminium<\/td><td>D<\/td><td>46<\/td><td>2&Prime;<\/td><\/tr><tr><th scope=\"row\">18794<\/th><td>MA-15-GX-10<\/td><td>150-760<\/td><td>25<\/td><td>Aluminium<\/td><td>A<\/td><td>49<\/td><td>3&Prime;<\/td><\/tr><tr><th scope=\"row\">981642<\/th><td>MA-15-TEX<\/td><td>150-757<\/td><td>25<\/td><td>Aluminium<\/td><td>B<\/td><td>46<\/td><td>3&Prime;<\/td><\/tr><tr><th scope=\"row\">18750<\/th><td>MSA-15-GX-10<\/td><td>150-757<\/td><td>25<\/td><td>Aluminium<\/td><td>E<\/td><td>&#8211;<\/td><td>3&Prime;<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<ul><li><strong>execution A<\/strong>: without temperature compensation<\/li><li><strong>execution B<\/strong>: with temperature compensation<\/li><li><strong>execution C<\/strong>: without temperature compensation and printer<\/li><li><strong>Ausf\u00fchrung D<\/strong>: with temperature compensation and EX-Pulser<\/li><li><strong>Ausf\u00fchrung E<\/strong>: version incl metrological test<\/li><\/ul>\n\n\n\n<h3>main parts of LC\/SAMPI PD meters (measurement units)<\/h3>\n\n\n\n<figure id=\"table_22773\" class=\"wp-block-table\"><table><thead><tr><th>FAS Nr.<\/th><th>part name<\/th><\/tr><\/thead><tbody><tr><th scope=\"row\">38395<\/th><td>diffrential valve 2&Prime; for LC meter<\/td><\/tr><tr><th scope=\"row\">98930<\/th><td>flow computer Register ME3000<\/td><\/tr><tr><th scope=\"row\">981631<\/th><td>flow computer TEX Register<\/td><\/tr><tr><th scope=\"row\">38466<\/th><td>printer Epson TM-U295, 24 Volt, f\u00fcr TEX\/ME3000<\/td><\/tr><tr><th scope=\"row\">38412<\/th><td>vapor eliminator<\/td><\/tr><tr><th scope=\"row\">38444<\/th><td>back check valve<\/td><\/tr><tr><th scope=\"row\">38459<\/th><td>3-way solenoid valve<\/td><\/tr><tr><th scope=\"row\">38334<\/th><td>impulse line for LC units<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div class=\"wp-block-columns\">\n<div class=\"wp-block-column\" style=\"flex-basis:16.67%\">\n<figure class=\"wp-block-image is-resized\"><a href=\"https:\/\/www.fas.de\/files\/FAS%20Dateien\/Produkte\/Messtechnik\/DSC_0119%20Kopie_result.jpg\"><img loading=\"lazy\" src=\"https:\/\/www.fas.de\/files\/FAS%20Dateien\/Produkte\/Messtechnik\/DSC_0119%20Kopie_result.jpg\" alt=\"For road tankers and stationery applications\u00a0 for LPG\" width=\"78\" height=\"73\"\/><\/a><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column\" style=\"flex-basis:16.67%\">\n<figure class=\"wp-block-image\"><a href=\"https:\/\/www.fas.de\/files\/FAS%20Dateien\/Produkte\/Messtechnik\/TEX_M7_Quadrat_.png\"><img src=\"https:\/\/www.fas.de\/files\/FAS%20Dateien\/Produkte\/Messtechnik\/TEX_M7_Quadrat_.png\" alt=\"For road tankers and stationery applications\u00a0 for LPG\"\/><\/a><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column\" style=\"flex-basis:16.67%\">\n<figure class=\"wp-block-image\"><a href=\"https:\/\/www.fas.de\/files\/FAS%20Dateien\/Produkte\/Messtechnik\/TEX_ohn_DV_Quadrat_.png\"><img src=\"https:\/\/www.fas.de\/files\/FAS%20Dateien\/Produkte\/Messtechnik\/TEX_ohn_DV_Quadrat_.png\" alt=\"For road tankers and stationery applications\u00a0 for LPG\"\/><\/a><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column\" style=\"flex-basis:16.67%\">\n<figure class=\"wp-block-image\"><a href=\"https:\/\/www.fas.de\/files\/FAS%20Dateien\/Produkte\/Messtechnik\/LC_Mech_Quadrat_.png\"><img src=\"https:\/\/www.fas.de\/files\/FAS%20Dateien\/Produkte\/Messtechnik\/LC_Mech_Quadrat_.png\" alt=\"For road tankers and stationery applications\u00a0 for LPG\"\/><\/a><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column\" style=\"flex-basis:16.67%\">\n<figure class=\"wp-block-image\"><a href=\"https:\/\/www.fas.de\/files\/FAS%20Dateien\/Produkte\/Messtechnik\/M30_LC_Quadrat_.png\"><img src=\"https:\/\/www.fas.de\/files\/FAS%20Dateien\/Produkte\/Messtechnik\/M30_LC_Quadrat_.png\" alt=\"For road tankers and stationery applications\u00a0 for LPG\"\/><\/a><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column\" style=\"flex-basis:16.67%\">\n<figure class=\"wp-block-image\"><a href=\"https:\/\/www.fas.de\/files\/FAS%20Dateien\/Produkte\/Messtechnik\/inkl%20printer_quadrat.png\"><img src=\"https:\/\/www.fas.de\/files\/FAS%20Dateien\/Produkte\/Messtechnik\/inkl%20printer_quadrat.png\" alt=\"For road tankers and stationery applications\u00a0 for LPG\"\/><\/a><\/figure>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>[vc_row_inner][vc_column_inner width=\u00a0\u00bb1\/2&Prime;][vc_single_image image=\u00a0\u00bb482&Prime; img_size=\u00a0\u00bbfull\u00a0\u00bb][\/vc_column_inner][vc_column_inner width=\u00a0\u00bb1\/2&Prime;][vc_column_text css=\u00a0\u00bb.vc_custom_1588858469372{margin-right: 50px !important;margin-left: 50px !important;}\u00a0\u00bb] PD METERS LIQUID CONTROLS PD METERS SAMPI For road tankers and stationery applications&nbsp; for LPG complete measuring unit typ LC MA5-LC MA7 &#8211; LC MA15 (PD meter) PD METER in ready to use design back check valve inlet vapor eliminator LC PD Meter mechanical counter &hellip; <a href=\"https:\/\/www.fas-northafrica.com\/fr\/products\/metering-units\/pd-meters-liquid-controls\/\" class=\"more-link\">Continuer la lecture<span class=\"screen-reader-text\"> de &laquo;&nbsp;<strong>PD METERS LIQUID CONTROLS<\/strong>&nbsp;&raquo;<\/span><\/a><\/p>\n","protected":false},"author":2,"featured_media":0,"parent":973,"menu_order":1,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/www.fas-northafrica.com\/fr\/wp-json\/wp\/v2\/pages\/2353"}],"collection":[{"href":"https:\/\/www.fas-northafrica.com\/fr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.fas-northafrica.com\/fr\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.fas-northafrica.com\/fr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.fas-northafrica.com\/fr\/wp-json\/wp\/v2\/comments?post=2353"}],"version-history":[{"count":3,"href":"https:\/\/www.fas-northafrica.com\/fr\/wp-json\/wp\/v2\/pages\/2353\/revisions"}],"predecessor-version":[{"id":2856,"href":"https:\/\/www.fas-northafrica.com\/fr\/wp-json\/wp\/v2\/pages\/2353\/revisions\/2856"}],"up":[{"embeddable":true,"href":"https:\/\/www.fas-northafrica.com\/fr\/wp-json\/wp\/v2\/pages\/973"}],"wp:attachment":[{"href":"https:\/\/www.fas-northafrica.com\/fr\/wp-json\/wp\/v2\/media?parent=2353"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}